Winlock
Facebook Instagram Linkedin

Out Lock

buitentoepassing

Out Lock

Fire Resistance
EN 16034-1: EI1/ EI2/ EW 60’, 90’, 120’, 180’, 240’
NBN 713.020
BENOR ATG EN 13501-2

Outdoor application
U-value 1,2 W/m2K water resistance

  • outdoor application: water resistance
  • tested on both sides
  • without irrigation
  • available to size, large dimensions are also available on request
  • combinable additional features
Contact us

Structure

  • Entire door leaf is guided into the rail profile using steel wheels (one wheel left and right of each panel)
  • Door leaf consists of several panels (composed of two 0.8 mm steel sheets)
  • Each module can be fitted with one or more fire-resistant glazing (max. three per panel)
  • WIPO 2.0 automatic control
  • As standard, doors always fitted on both sides with a 20μ powder coating in one of the standard RAL colours below
  • RAL 3000
  • RAL 9010
  • RAL 9002
  • RAL 9006
  • RAL 7016
  • RAL 9005

Finish options on request

On top of the steel cladding:

  • Paint or varnish layer
  • Wood-veneer sheet of your choice with a max. thickness of 1.5 mm
  • Laminate sheet with thickness of 0.5 mm
  • Personalised stickering

As a variant to steel sheet:

  • Stainless-steel cladding, max. thickness 0.65 mm
  • Galvanised sheet cladding, max. thickness 0.65 mm

References

luminus
gent

Vindevogel
Kruishoutem

Aldi
Brugge

More projects