These industrial sectional doors offer excellent thermal insulation down to -23°C and can optionally be made fire-resistant.
Frost Lock is the ideal solutions for applications where negative temperatures prevail on both sides of the door, such as freezer warehouses, cold corridors, and deep-freeze storage areas within temperature-controlled production or logistics facilities. These isothermal doors minimise energy loss and enhance fire safety in temperature-controlled environments. They integrate seamlessly into a comprehensive fire compartmentation system, physically separating cold zones to slow fire propagation and safeguard the continuity of critical processes.
For even more extreme environments, we developed Cryo Lock, designed for cryogenic applications down to –60 °C, where conventional systems are no longer sufficient.
Technical specifications Frost Lock:
Thermal range: -23 °C
U-value: 1,2 Wm²K
Insulation thickness: minimum 80 mm
Finish: Powder-coated or stainless steel
Maximum width: 7,440 mm
Maximum height: 7,223 mm
Maximum surface area: 45 m² / Fire-resistance version: 35 m²
Various fire resistance levels available:
– EI1 60, EI1 120, EI1 180, EI1 240
– EN 13501-2
– EN 1634-1: EI1/ EI2/ EW