This sectional shutter has been specifically engineered for environments that are frequently exposed to high wind pressure, such as coastal regions, high-rise buildings, airports, wind farms, ports, or tunnels. It ensures reliable protection of infrastructure and enables critical operations to continue even under extreme wind load conditions.
Depending on the project requirements, doors can be designed to comply with wind resistance Classes 1 through 5. Class 5 is the highest category, without an upper limit, and always requires a project-specific structural assessment.
As with all our solutions, customization is essential: our wind-resistant Wind Lock application can also be combined with additional performance features such as fire resistance, acoustic insulation, smoke control, or explosion protection – fully adapted to your project’s specific needs.
Technical specifications Wind Lock:
Test standard: EN 12444
Classification standard: EN 12424
Class 1: 300 Pa*
Class 2: 450 Pa*
Class 3: 700 Pa*
Class 4: 1,000 Pa*
Class 5: >1,000 Pa*
*Peak wind pressure
Various fire resistance levels available:
– EI1 60, EI1 120, EI1 180, EI1 240
– EN 13501-2
– EN- 1634-1: EI1/ EI2/ EW