Pressure Lock

Characteristics

Our industrial sectional shutters are specifically engineered for environments where overpressure or underpressure can occur, such as cleanrooms, airlocks or CO₂ extinguishing systems. In these situations, it is crucial that the door remains structurally intact while maintaining full fire compartment integrity.

This type of industrial shutter is also designed to withstand blast waves from external explosions (blast resistance) without any structural failure. The construction absorbs both positive and negative pressure loads as well as the dynamic impulse of the explosion, a key requirement in demanding sectors such as petrochemical industries, defence, ATEX environments, and nuclear facilities.

Technical specifications Pressure lock:

  • Pressure resistance: 10 kPa
  • Design calculation according to: EN1990, E1193-1-1 to 8, EN 10088-3, EN 10149-2, EN 1090-2 & EN 338
  • Maximum width: 7,440 mm
  • Maximum height: 7,227 mm
  • Maximum surface area: 35.85 m²

Various fire resistance levels available:

– EI1 60, EI1 120, EI1 180, EI1 240
– EN 13501-2
– EN 1634-1: EI1/ EI2/ EW

  • Tested on both sides
  • Without irrigation
  • Extremely robust
  • Fully autonomous operation
  • Available with colour finishes and to order
  • Failsafe
  • Functional shutter

Additional features

Winlock shutters can combine different features. Depending on your needs, one or more features can be added to the standard Winlock.

Winlock, Liquid lock, Out lock, Food lock, Safe lock, Noise lock, Wind lock, Smoke lock, Frost lock, Quake lock, Atex, Air lock, Cryo lock, Opti lock

Built-in options

Reduced lift

For restricted overhead clearance

Horizontal lift

From 600mm overhead clearance

Inclined lift

Angle of slope <45°

Vertical lift

Vertical upwards

Installation walls

Concrete block masonry

Autoclaved aerated concrete

Concrete blocks

Fire resistant mineral wool panels

Poured concrete

Rapid-build masonry

Gyproc

Choose your country

By selecting your country you will see local offers and information.

Fill in the information below and we will be happy to send the technical sheet

Make your selection:
Fire resistant?

Request product information

Make your selection:
Fire-resistant?

Indoor or outdoor application?
General conditions
Left Menu Icon