The Outlock industrial sectional shutters are specifically engineered for outdoor applications. Whether used for external loading and unloading areas, façade openings in the building envelope, or stand-alone external facilities, this door ensures a reliable seal, resistant to various weather conditions and intensive industrial use.
The thermal performance of Outlock is calculated in accordance with EN 12428, making this solution ideal for applications where energy efficiency is also a key factor.
Technical specifications Out lock:
Thermal transmittance: UD = 1,2 Wm²K
Test standard: EN 12428
Insulation thickness: Minimum 80 mm
Maximum surface area: 45 m²
Various fire resistance levels available:
– EI1 60, EI1 120, EI1 180, EI1 240
– EN 13501-2
– EN 1634-1: EI1/ EI2/ EW